Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Salud UNINORTE ; 38(1)ene.-abr. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1536789

RESUMO

Objetivo: Describir el comportamiento de la glucosa y la insulina durante las etapas del ejercicio en atletas acondicionados en ejercicio aeróbico y anaeróbico. Materiales y métodos: En un estudio cuasiexperimental de corte transversal se compararon la glucosa e insulina de 6 atletas anaeróbicos y 10 aeróbicos durante el reposo, ejercicio de moderada - alta intensidad y la recuperación. Se eligió un valor p de <0.05, se encontró distribución no-normal y se utilizaron pruebas no paramétricas y modelos de regresión linear. Resultados: El ejercicio moderado llevó a hipoinsulinemia, y el intenso a hiperinsulinemia e hiperglicemia. No encontramos diferencias entre los dos tipos de atletas. Conclusiones: El comportamiento del sistema nervioso autónomo afectaría el balance glucoenergético corporal durante el ejercicio aún más que la insulina, con variaciones dependiendo del tipo de entrenamiento, pero es necesario realizar estudios adicionales para evaluar esta relación.


Objective: Describe glucose and insulin behavior at the different phases of exercise in aerobic and anaerobic athletes. Materials and methods: Glucose and insulin from 6 anaerobic and 10 aerobic athletes were compared during rest, moderate-high intensity exercise, and recovery. Statistical analysis was performed to evaluate insulin and glucose behavior, and differences between aerobic aerobic and anaeribic-trained individuals. A p value of <0.05 was set. A non-normal distribution was found, non-parametric tests and multivariate analysis were performed. Results: Moderate exercise led to hypoinsulinemia, whereas intense exercise caused hyper-insulinemia and hyperglycemia. No differences were found between the 2 groups. Conclusions: Autonomic nervous system behavior may play a role in the glucoenergetic balance that could overcome insulin effect, and it could vary depeding on the type of exercise régimen but further evaluation is necessary to confirm these findings

4.
Rev. colomb. anestesiol ; 46(2): 177-177, Apr.-June 2018.
Artigo em Inglês | LILACS, COLNAL | ID: biblio-959799

RESUMO

Reply to Letter to the Editor


Assuntos
Humanos
5.
Rev. bras. med. esporte ; 23(4): 317-321, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-898985

RESUMO

ABSTRACT Introduction: The maximum oxygen consumption (VO2max) is the gold standard in the cardiorespiratory endurance assessment. Objective: This study aimed to develop a mathematical model that contains variables to determine the VO2max of sedentary people. Methods: Twenty participants (10 men and 10 women) with a mean age of 19.8±1.77 years were included. For each participant, body composition (percentage of fat and muscle), heart rate variability (HRV) at rest (supine and standing), and VO2max were evaluated through an indirect test on a cycloergometer. A multivariate linear regression model was developed from the data obtained, and the model assumptions were verified. Results: Using the data obtained, including percentage of fat (F), percentage of muscle (M), percentage of power at very low frequency (VLF), α-value of the detrended fluctuation analysis (DFAα1), heart rate (HR) in the resting standing position, and age of the participants, a model was established for men, which was expressed as VO2max = 4.216 + (Age*0.153) + (F*0.110) - (M*0.053) - (VLF*0.649) - (DFAα1*2.441) - (HR*0.014), with R2 = 0.965 and standard error = 0.146 L/min. For women, the model was expressed as VO2max = 1.947 - (Age*0.047) + (F*0.024) + (M*0.054) + (VLF*1.949) - (DFAα1*0.424) - (HR*0.019), with R2 = 0.987 and standard error = 0.077 L/min. Conclusion: The obtained model demonstrated the influence exerted by body composition, the autonomic nervous system, and age in the prediction of VO2max.


RESUMO Introdução: O consumo máximo de oxigênio (VO2máx) é o padrão-ouro na avaliação da resistência cardiorrespiratória. Objetivo: Este estudo visou desenvolver um modelo matemático com as variáveis usadas na determinação do VO2máx em indivíduos sedentários. Método: Vinte indivíduos (10 homens e 10 mulheres) com média de idade 19,8±1,77 anos foram incluídos. Para cada participante, foram avaliados composição corporal (percentual de gordura e de músculo), variabilidade da frequência cardíaca (VFC) em repouso (em decúbito dorsal e em pé) e o VO2máx, empregando-se o protocolo em cicloergômetro, método indireto. A partir dos dados obtidos, desenvolveu-se um modelo de regressão linear multivariado e os pressupostos do modelo foram verificados. Resultados: Usando os dados obtidos, incluindo percentual de gordura (G), porcentagem de músculos (M), porcentagem de energia em frequência muito baixa (FMB), valor de α da análise de flutuação sem tendências (DFAα1), frequência cardíaca (FC) em repouso na posição em pé e a idade dos participantes, estabeleceu-se um modelo para homens, expresso como: VO2máx = 4,216 + (Idade*0,153) + (G*0,110) - (M*0,053) - (FMB0,649*) - (DFAα1*2,441) - (FC*0,014) com R2 = 0,965 e erro padrão = 0,146 L/min. Para as mulheres, o modelo foi expresso como: VO2máx = 1,947 - (Idade*0,047) + (G*0,024) + (M*0,054) + (FMB*1,949) - (DFAα1*0,424) - (FC*0,019) com R2 = 0,987 e erro padrão de 0,077 L/min. Conclusão: O modelo desenvolvido demonstrou a influência exercida pela composição corporal, pelo sistema nervoso autônomo e pela idade na predição do VO2máx.


RESUMEN Introducción: El consumo máximo de oxígeno (VO2max) es el patrón áureo en la evaluación de la resistencia cardiorrespiratoria. Objetivo: Este estudio tuvo como objetivo desarrollar un modelo matemático con las variables que participan en la determinación del VO2max en individuos sedentarios. Método: Veinte sujetos (10 hombres y 10 mujeres) con edad promedio de 19,8 ± 1,77 años se han incluido. Para cada participante, se evaluó la composición corporal (porcentaje de grasa y músculo), variabilidad de la frecuencia cardiaca (VFC) en reposo (decúbito supino y en pie) y VO2max mediante un test indirecto en cicloergómetro. A partir de los datos obtenidos se desarrolló un modelo de regresión lineal multivariado y se comprobaron los supuestos del modelo. Resultados: Usando los datos obtenidos, incluyendo porcentaje de grasa (G), porcentaje de músculos (M), porcentaje de energía en frecuencia muy baja (FMB), valor de α del análisis de fluctuación sin tendencias (DFAα1), frecuencia cardiaca (FC) en reposo en la posición en pie y la edad de los participantes, se estableció un modelo para hombres que se expresa como VO2max = 4,216 + (Edad*0,153) + (G*0,110) - (M*0,053) - (FMB*0,649) - (DFAα1*2,441) - (FC*0,014) con R2 = 0,965 y error típico = 0,146 L/min. Para las mujeres el modelo se expresó como VO2max = 1,947 - (Edad*0,047) + (G*0,024) + (M*0,054) + (FMB*1,949) - (DFAα1*0,424) - (FC*0,019) con R2 = 0,987 y error típico de 0,077 L/min. Conclusión: El modelo desarrollado demostró la influencia ejercida por la composición corporal, el sistema nervioso autónomo y la edad en la predicción del VO2max.

6.
Rev. colomb. anestesiol ; 44(3): 193-200, July-Sep. 2016. ilus, tab
Artigo em Inglês | LILACS, COLNAL | ID: lil-791215

RESUMO

Introduction: There are two different pharmacokinetic models (Marsh and Schnider) for the administration of total intravenous anesthesia with propofol, the parameter differences could have some impact over the depth of anesthesia. Objective: To determine if there is a significant difference in the variability of depth of anesthesia suggesting that one model is superior in achieving a more stable and predictable depth of anesthesia during surgery. Methods: A cross-over clinical trial was conducted on 16 healthy patients programmed for upper or lower limb ambulatory orthopedic surgery. Patients were randomly assigned to (i) effect site target controlled infusion of propofol with Marsh model at a target concentration of 2.5 μg/ml for 20 min, a 20 min washout, then propofol was administered with Schnider model at the same effect site target for the reminder of the surgery, or (ii) the reverse sequence. Differences in variability of depth of anesthesia, were assessed by comparing records of spectral entropy indices during surgery through an unpaired t-test. Results: There was no evidence of significant difference in the mean variances of either spectral entropy indices between the two models (p-value: 0.57 for State Entropy, p-value: 0.51 for Response Entropy). Conclusion: The study suggests that both pharmacokinetic models are equivalent in terms of stability of depth of anesthesia. It is important to keep testing determinants of the efficacy of the models in different types of population because their behavior according to individual characteristics of patients or variables such as cost-effectiveness could end up tilting the scale.


Introducción: Hay dos modelos farmacocinéticos diferentes para la administración de la anestesia total intravenosa con propofol (Marsh y Schnider), las diferencias entre los parámetros podrían tener algún impacto sobre la profundidad anestésica. Objetivo: Comparar la variabilidad de la profundidad anestésica durante administración de infusión de propofol con los modelos de Marsh y Schnider para determinar si hay diferencias significativas que sugieran que uno de los modelos es superior en lograr una profundidad anestésica más estable y predecible. Métodos: Estudio clínico cruzado, controlado y aleatorizado llevado a cabo en 16 pacientes programados para cirugía ambulatoria de ortopedia. Los pacientes fueron asignados aleatoriamente a i) infusión controlada por objetivo de propofol con el modelo de Marsh a una concentración objetivo en sitio de efecto de 2.5μg/ml durante 20 minutos, 20 minutos de periodo de lavado, seguido de infusión de propofol con modelo de Schnider a la misma concentración objetivo; o ii) la secuencia inversa. La diferencia en variabilidad de profundidad anestésica fue evaluada mediante la comparación de registros de índices de entropía con una prueba t no pareada. Resultados: No se encontró evidencia de diferencias significativas de la varianza media en los índices de entropía espectral asociada a los modelos (valor-p: 0.57 para entropía de estado, valor-p: 0.51 para entropía de respuesta). Conclusión: El estudio sugiere que ambos modelos son equivalentes en términos de estabilidad de profundidad anestésica. Es importante continuar estudiando la eficacia de los modelos en diferentes tipos de población, dado que su comportamiento según características individuales de los pacientes o variables cómo costo-efectividad podrían inclinar la balanza.


Assuntos
Humanos
7.
Rev. Fac. Med. (Bogotá) ; 62(4): 587-592, Oct.-Dec. 2014. ilus, tab
Artigo em Inglês | LILACS | ID: lil-742685

RESUMO

Voltage-gated sodium channels constitute a group of membrane proteins widely distributed thought the body. In the heart, there are at least six different isoforms, being the Nav1.5 the most abundant. The channel is composed of an α subunit that is formed by four domains of six segments each, and four much smaller β subunits that provide stability and integrate other channels into the α subunit. The function of the Nav1.5 channel is modulated by intracellular cytoskeleton proteins, extracellular proteins, calcium concentration, free radicals, and medications, among other things. The study of the channel and its alterations has grown thanks to its association with pathogenic conditions such as Long QT syndrome, Brugada syndrome, atrial fibrillation, arrhythmogenic ventricular dysplasia and complications during ischemic processes.


Los canales de Sodio dependientes de voltaje constituyen un grupo de proteínas de membrana ampliamente distribuidas en el cuerpo humano. En el corazón se dispone de al menos seis diferentes isoformas de estos canales: los Nav1.5 son los más abundantes. El canal está constituido por una subunidad α, formada por cuatro dominios, cada uno de estos con seis segmentos y cuatro subunidades β mucho más pequeñas que estabilizan la estructura e integran la subunidad α de otros canales. La función del canal Nav1.5 se ve modulada por proteínas del citoesqueleto, proteínas extracelulares, concentraciones de calcio, radicales libres, medicamentos, entre otros. El estudio del canal y sus alteraciones se ha incrementado gracias a la asociación de este con condiciones patológicas como el síndrome de QT largo, el síndrome de Brugada, la fibrilación auricular, la displasia ventricular arritmogénica y por las complicaciones de en procesos isquémicos.

8.
NOVA publ. cient ; 11(19): 65-72, Jan.-June 2013. ilus, tab
Artigo em Espanhol | LILACS, COLNAL | ID: lil-729494

RESUMO

Pythium insidiosum es un hongo distribuido globalmente causante de una micosis emergente llamada Pitiosis en personas y animales. El diagnóstico definitivo involucra correlación clínico epidemiológica, clínico patológica, histopatológica y molecular. En Colombia no existen antecedentes diagnósticos de Pitiosis con estas correlaciones. Pitiosis fue demostrada dos equinos de zona rural en Puerto Boyacá, Departamento de Boyacá-Colombia. Los equinos presentaron en extremidades lesiones únicas, pruriginosas, ulceradas, granulomatosas, alternada de masas sólidas con secreción serosanguinolenta. De las biopsias los hallazgos anatomopatológicos demostraron masas sólidas de aspecto coralino, las cuales se procesaron histopatológicamente. Los resultados correlacionados de biogeografía, las lesiones halladas en los equinos y en ellas los patrones histopatológicos de Splendore-Hoeplii, con hallazgos de hifas raramente septadas con diámetro de 2,5 a 6,2 micras en ramificación angulada, junto a la secuenciación del DNA extraído y comparado con el depositado para P.insidiosum en el GenBank permitió demostrar en todas las muestras una homología del 100% conformándose por primera vez el diagnóstico definitivo de Pitiosis en Colombia.


Pythium insidiosum is a globally distributed fungus that causes a fungal infection called Pythiosis is considered an emerging disease in humans and animals. A definitive diagnosis involves clinical, epidemiological, histopathological and molecular correlations. There are no reports of Pythiosis diagnosis involving all these correlations in Colombia. In this study were confirmed Phytiosis in two horses in rural area of Puerto Boyaca (Boyaca, Colombia) presenting single,itching, ulcerated, granulomatous lesions on their limbs with serosanguineous suppuration. Biopsies were analyzed pathologically and histopathologically. Polymerase Chain Reaction (PCR) was carried out from DNA extracted of paraffin blocks. This study report the first definitive diagnosis of phytiosis in Colombia based on the correlation between biogeography area, the pathological and histopathological findings which included patterns like Splendore-Hoeplii and hyphae with rare septae (2.5 to 6.2 microns diameters of branching angled) along with sequenced DNA that showed 100% homology with the Pythium insidiosum sequence at the GenBank.


Assuntos
Humanos , Micoses , Pythium , Pitiose , Fungos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA